Product Features
● High-resolution C-T structure monochromator, good stability, reproducibility and accuracy.
● Advanced ARM microcomputer technology, excellent electronic circuit and signal processing, stable and reliable data, U disk data storage and export, one-click software upgrade, Bluetooth printing and other data outputs.
● Integrated aviation-grade aluminum alloy substrate, machined reflector seat to ensure long-term stability of the optical path.
● 7-inch color large-screen graphic LCD display, with navigation menu interface design, clear operation commands, and special functions to prevent user errors. Users can operate without checking the manual; touch screen + button dual operation mode, can also be operated with gloves.
● Strict manufacturing process and 32 key quality control points make each instrument very durable.
● Large-capacity memory, can store massive test data.
● Tungsten lamps, photocells, precision screws and other key components are all selected from well-known and imported brands to ensure the quality of the instrument.
● Four-slot 10-50mm universal adjustable manual sample holder to facilitate the testing needs of cuvettes of different specifications.
● Independently designed deuterium lamp and tungsten lamp replacement windows for easy replacement.
Product functions
1. Photometric measurement: You can select the single-point test wavelength and test method you need within the range of 320-1100nm to measure the absorbance or transmittance of the sample. You can also directly read the concentration of the sample by entering the standard concentration or concentration factor.
2. Quantitative measurement: Measure sample solutions of unknown concentrations through curves of known parameter factors or automatically establish standard solution curves; with first-order\first-order zero-crossing, second-order, third-order curve fitting, and single wavelength correction, dual wavelength correction, three-point method optional; standard curves can be stored and called.
3. Qualitative measurement: Set a wavelength range, scan intervals, and then measure the absorbance, transmittance, reflectivity and energy of solid or liquid samples at intervals. You can also overlay, zoom, smooth, filter, peak and valley detection, save, print, etc. of the measured spectra.
4. Time measurement: Time measurement is also called kinetic measurement. The sample is scanned at intervals of the time range of absorbance or transmittance at the set wavelength point. The absorbance can also be converted into concentration or reaction rate calculation by inputting the concentration factor.
Enzyme kinetic reaction rate calculation. You can also choose from a variety of spectrum processing methods such as superposition, scaling, smoothing, filtering, peak and valley detection, and derivation of the measured spectrum.
5. Multi-wavelength measurement: It can set multiple wavelength points to measure the absorbance or transmittance of the sample solution. N wavelength test wavelengths can be set to test the absorbance and transmittance values at a single wavelength.
6. Instrument calibration measurement: Built-in special wavelength maximum allowable error calibration, transmittance maximum allowable error measurement, and stray light measurement.
7. Additional functions: deuterium lamp, tungsten lamp lighting cumulative time, deuterium lamp, tungsten lamp independent shutdown and opening, ultraviolet and visible light switching wavelength point selection, operating language selection (Chinese, English), wavelength automatic calibration, Bluetooth function, etc.
8. Optional PC reverse control software package functions: quantitative measurement, qualitative measurement, time measurement, multi-wavelength measurement, 3D graphics analysis, spectrum overlay analysis, etc.
SPECIFICATIONS
Model | LVD-8 |
Optical system | Dual beam; 1200 lines/mm holographic grating |
Wavelength range (nm) | 320-1100 |
Spectral bandwidth (nm) | 1.8 |
Wavelength accuracy (nm) | ±0.5 |
Wavelength repeatability (nm) | ≤0.1 |
Transmittance accuracy (%T) | ±0.3 |
Transmittance repeatability (%T) | ≤0.1 |
Noise (%T) | 0% line 0.05; 100% line 0.1 |
Drift (Abs) | ≤0.001 |
Baseline flatness (Abs) | ±0.001 |
Stray light (%T) | ≤0.05@360nm |
Power supply voltage adaptability (%T) | ≤0.2 |
Luminous range | 0-200%T, -0.301-3A, 0-9999C(0-9999F) |
Test mode | Transmission, reflection, absorbance, concentration, energy |
Light source | Tungsten lamp |
Display | 7-inch touch screen display (resolution 800*480) |
System language | Chinese, English, Russian, Spanish |
Software upgrade | Support USB one-key upgrade |
Data output | USB, Bluetooth, USB software upload |
Data output format | CSV |
Operation mode | Touch screen |
Sample rack | Four-slot 10-50mm universal adjustable manual sample rack |
Host function | Basic + quantitative + qualitative + time + multi-wavelength |
Printer | Optional, support Bluetooth printing |
Power supply range | AC90~250V/ 50~60Hz |
Dimensions (L×W×H) mm | 470×330×210 |
Weight (kg) | 12kg |